Print Back
A microprocessor control for the regulation of the viscosity of the ink solvent that happens thanks to a vibration sensor.
Microprocessor Control System for Solvent-Based Inks
Unit of Measure
Items Microprocessor Control System for Solvent-Based Inks
VIS-G26
Microprocessor Control System for Solvent-Based Inks
Microprocessor Control System for Water and Solvent-Based Inks
VIS-G29
Microprocessor Control System for Water and Solvent-Based Inks
Description N/A The VIS-G26 is a system for the regulation of the viscosity of the solvent-based inks. The measurement of the viscosity takes place thanks to a vibration sensor immersed in the liquid to be analyzed, without moving parts.

It, in series with the flow, emits a frequency that in contact with the liquid is changed, may alternatively also be installed in derivation to the ink flow.

From the analysis extrapolates the viscosity in seconds (cup ZAHN, FORD, …) and by the correction valve maintains the management based on the reference set. The cleaning of the viscometer performed at the end of work, at the same time washing the inking circuit.
N/A The VIS-G29 is a system for the regulation of the viscosity of inks based on water and solvent. The measurement of the viscosity takes place thanks to a vibration sensor immersed in the liquid to be analyzed, without moving parts.

It, in series with the flow, emits a frequency that in contact with the liquid is changed, may alternatively also be installed in derivation to the ink flow.

From the analysis extrapolates the viscosity in seconds (cup ZAHN, FORD, …) and by the correction valve maintains the management based on the reference set. The cleaning of the viscometer performed at the end of work, at the same time washing the inking circuit.
Brands N/A isi
Control G26-VID N/A
  • Rack system cabled by connectors.
  • Installed in a box chosen by the Costumer.
  • Serial communication between PC and control.
N/A
Stand Alone Control G26-LCD N/A
  • Backlighted LCD 20 x 4 display and keyboard membrane for data setting.
  • In option or instead of the PC touchscreen.
N/A
Detector G26-RIV N/A
  • Solvent correction through pneumatic valve.
  • Feeding by rotary or alternative pumps.
  • Viscosity is measured with 1% accuracy.
N/A
Console and Command Panel N/A
  • PC with 15" touchscreen monitor.
  • Visualization of all colors controlled, on the same screen.
  • Visualization of viscosity by a graphic bar.
  • Choice of the reference cup, set of the viscosity reference.
  • It is possible to save until 1000 different works.
  • Temperature compensation.
  • Error signalization (no ink, no solvent or viscosity over tolerance).
N/A
Options N/A
  • All Underwriters Laboratories (UL) electrical components.
  • Complete Underwriters Laboratories (UL) approval
  • Additional safety package for North America